Doosan Infracore D18NAP — P0003 Rail pressure control feedback low fault

5. Failure Diagnosis P0003 Rail pressure control feedback low fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the resistance of IMV is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the resistance of IMV is within the threshold during restricted condition, fault code is cleared. 5.

Inspection Items 5 - 110 Code Causes Impact P0003 Electrical problem Connection problem Resistance problem CE lamp ON Torque Reduction Lv0 NO ECU Pin Description 1 177 Inlet Metering Valve PWM 2 - Pbatt Step Inspection Standard Value YES NO 1 P0003 is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Check the IMV connection Connection problem? (pin to pin) Do necessary repair Step 4 4 Check the ECU Connection. Connection problem? Do necessary repair Step 5 5 Check continuity and electrical insulation. Electrical problem? Fix wire harness Step 6 6 Measure IMV electrical resistance? (around 5.3 at 20°C) Resistance problem?

Change IMV Step 7 7 Perform IMV buzzing test? (Test not applicable) IMV is buzzing? Call Hot-Line Change IMV