Doosan Infracore D18NAP — P0259 RPC error (IMV current trim drift high/high)

5. Failure Diagnosis P0259 RPC error (IMV current trim drift high/high) 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the current of IMV trim value is out of the threshold, fault code is raised. 4. Condition for Clearing the Fault Code If the current of IMV trim value is within the threshold, fault code is cleared. 5. Inspection Items 1) A 5 - 111 Code Causes Impact P0259 There is a problem in the ADC of the ECU or the power supplied to the torque converter switch. CEL is ON. NO ECU Pin Description 1 177 Inlet Metering Valve PWM 2 - Pbatt Step Inspection Standard Value YES NO 1 P0259 is occurred on diagnostic tool?

Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch. Step 3 3 Please do visual inspection throughout all fuel line. (Low pressure circuit & high pressure circuit) Is there any leakage or blocking of fuel? If you cannot find with your eyes, You can check leakage during engine running in machine stationary condition. Step 4 Step 5 4 Please fix the leakage. After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 10 minutes. Fault code is cleared? O.K Step 5 5 Please do the Shut off test & Run up test for detecting which injector has fault or not. Do you find faulty injector?

Step 6 Step 7 6 Change the injector which has a fault as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Step 7 7 Change the high pressure pump with DOOSAN A.S support. Fault code is cleared? O.K Call DOOSAN Hot line