5. Failure Diagnosis P2080 Turbo in temperature plausibility fault 1. Overview 2. Condition for Running Diagnostic During engine running 3. Condition for Setting the Fault Code If the turbine in temperature is out of the threshold during restricted condition, fault code is raised. 4. Condition for Clearing the Fault Code If the turbine in temperature is within the threshold during restricted condition, fault code is cleared. 5.
Inspection Items 5 - 122 Code Causes Impact P2080 Leakage Electrical problem Connection problem Sensor problem NO ECU Pin Description 1 123 Exhaust gas temp 2 (Pre-Turbo), return 2 106 Exhaust gas temp 2 (Pre-Turbo), signal Step Inspection Standard Value YES NO 1 P2080 is raised on machine dashboard? Step 2 O.K 2 After let the machine be in safety area and turn-off the key switch. Step 3 3 Please do visual inspection throughout all air path. (From air cleaner to exhaust manifold including EGR passage) Is there any leakage? If you cannot find with your eyes, You can check leakage during engine running in machine stationary condition. Step 4 Step 5 4 Please fix the leakage.
After fix the problem, start the engine and change the RPM from low idle to high idle. Please keep the RPM as a high idle at least 10 minutes. Fault code is cleared? O.K Step 5 5 Change the turbine in temperature sensor as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Call DOOSAN Hot line