Doosan Infracore D18NAP — P068A Main relay unexpected low state

5. Failure Diagnosis P068A Main relay unexpected low state 1. Overview 2. Condition for Running Diagnostic Key ON or Engine Run 3. Condition for Setting the Fault Code If main relay status to be low state. If abnormal shutdown happened by battery disconnection. 4. Condition for Clearing the Fault Code When normal shutdown happened and main relay is operating normally. 5.

Inspection Items 5 - 127 Code Causes Impact P068A Electrical problem Connection problem Relay problem CE lamp ON NO ECU Pin Description 1 201 Protected Battery 2 203 Protected Battery 3 205 Protected Battery 4 202 Power Ground 5 204 Power Ground 6 206 Power Ground Step Inspection Standard Value YES NO 1 P068A is occurred on diagnostic tool? Step 2 2 After let the machine be in safety area and turn-off the key switch Step 3 3 Perform relay test routine Test OK? Call Hot-line Step 4 4 Check relay connection Connection problem? Do necessary repair Step 5 5 Check ECU connection Connection problem? Do necessary repair Step 6 6 Check continuity and electrical insulation Electrical problem?

Fix harness Step 7 7 Change relay (run ISO cycle) ISO cycle OK? Problem solved Call Hot-line