7. Cooling System Check of Thermostat Thermostat Assembly 1. Check whether the wax pellet and the spring are 1. Attach the thermostat. damaged or not. 2. Put the thermostat into water and heat the water 3. If the thermostat starts open approximately 0.3 slowly to inspect thermostat operation. mm at a water temperature of 82°C and is fully open at more than 8.0 mm at a water temperature of 97 °C, the thermostat is normal. B A EDL013016A 1) Attach the thermostat (A) to the cylinder head. 2) Tighten 3 flange hex bolts (B) at a tightening 3) Tighten the space bolt and the flange hex nut (C) torque of 2.2 kgf m. at a tightening torque of 2.2 kgf m. 4) Connect the rubber hose (D). A.
Thermometer B. Measuring point EDL022212A 5) Attach the water temperature sensor (E). CAUTION 4. Check if there are any foreign substances in the After mounting the hose clamps, make the protrusion face the cylinder head side to prevent interference between the protrusion and the water pump pulley. thermostat. Note) Clean the inside of the thermostat with an air gun. Do not use the hose clamps more than twice; replace them with new ones. 5. Check if there are any foreign substances or damaged parts inside and outside of the hose. 2. Replenish the coolant. 7 - 9 A C E B D Item Specified Value thermostat Open Temperature 0.3 mm (at 82 °C) 8.0 mm or larger (at 97 °C)