Doosan Infracore D18NAP — P0088 Rail pressure control fault

5. Failure Diagnosis 2) B 5 - 21 Step Inspection Standard Value YES NO 6 Change the injector which has a fault as a normal one. Start the engine and set the RPM in high idle at least 10 minutes. Fault code is cleared? O.K Step 7 7 Change the high pressure pump with DOOSAN A.S support. Fault code is cleared? O.K Call DOOSAN Hot line Step Inspection Standard Value YES NO 1 P0088 is occurred on diagnostic tool? Step 2 2 Fault of type IMV or rail pressure sensor? First, fix the corresponding fault Step 3 3 DTC link to High Pressure control? Step 4 No problem 4 Check that:

* fuel feed circuit is in good condition * there is diesel fuel present in the system * there is no air (no bubbles or emulsion in the pipes) * there is enough fuel pressure in inlet pump * there are no high pressure circuit leaks * there is diesel fuel of the correct quality and type Low pressure circuit faulty? Repair the low pressure circuit Step 5 5 According to engine start or not, different tests are to be done. Does engine start? Step 6 Step 7 6 Perform "DYNAMIC IMV TEST" Faulty IMV? Replace IMV Step 8 7 Perform "STATIC INJECTOR BACKLEAK TEST" Carry out the "tube test: Result?

Replace corresponding injector(s) Replace HP pump 8 Perform "DYNAMIC INJECTOR BACKLEAK TEST" Backleak above limit? Replace corresponding injector(s) Step 9 9 Perform "PUMP PRESSURE BUILD CAPACITY" This test need specific equipment "hydraulic-T" Result? End Replace HP pump