Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER

. MAINTENANCE SERVICE PROCEDURE 4 - 23 REPLACING INNER ELEMEN 1. First re move the cover a nd t he out er element, and th en remove the inner element. 2. Cover t he air connector side (outle t side ) with a clea n cloth or tape. 3. Clean t he air cleaner body in terior , then remov e the cover installed in Step 2. 4. Install a new inne r element t o the body. Do not clean and re-use an i nner e leme 5. Install t he outer e lement and the c over. 6. Remov e evacuat or valv e (4) and c lean i t with c ompressed air. After cleaning, install it again. 7. After re placing th e element, return the re d line of the dust i ndicator to its original position.