03-M-E3B, 03-M-DI-E3B, 03-M-E3BG WSM G GENERAL [12] CHECK POINTS OF EVERY 1500 HOURS CAUTION Check the injection pressure and condition after confirming that there is nobody standing in the direction the fume goes. If the fume from the nozzle directly contacts the human body, cells may be destroyed and blood poisoning may be caused. Nozzle Spraying Condition [D1503-M, D1703-M, D1803-M, V2003-M, V2203-M, V2403-M, V2403-M-T] [D1703-M-BG, V2003-M-BG, V2003-M-T-BG, V2203-M-BG, V2403-M-BG] 1. Set the injection nozzle to a nozzle tester, and check the nozzle spraying condition. 2. If the spraying condition is defective, replace the nozzle piece.

(a) Good (b) Bad W10411400 [D1803-M-DI, V2403-M-DI, V2403-M-DI-T] 1. Set the injection nozzle to a nozzle tester, and check the nozzle spraying condition. 2. If the spraying condition is defective, replace the injection nozzle assembly. (a) Good (b) Bad W1037040 G-28 KiSC issued 07, 2008 A