MAN Nutzfahrzeuge Aktiengesellschaft — Removing and installing oil cooler

Removing and installing oil cooler D Drain coolant, see page 46 D Remove oil filter, see page 63 Caution: Used oil and oil filter cartridges are dan- gerous waste. Observe safety regulations to prevent damage to the environment. Fig. 1 Remove oil filter head (5 bolts). Take off filter head gasket. 1 Fig. 2 Remove oil cooler housing cover with the oil cooler attached. The oil cooler is secured by the 10 bolts marked. Loosen these screws only after removal of the housing cover. 2 Fig. 3 Check both oil cooler for damage and if necessary replace them. Fit oil cooler with new gaskets. 3 Fig. 4 Tighten the mounting bolts to the specified torque.

D Screw on oil cooler housing cover together with attached oil cooler D Attach oil filter head and oil filter with new seals, see also page 63 D Top up with engine oil, let engine run briefly and then check for leaks D Check oil level D Filling up with coolant, see page 46 4 64