Doosan — Doosan D60S-5 and G60S-5 Lift Truck Operation Manual

Operation Section Table 2. MI-07 Diagnostic Fault Codes (Flash Codes) cont’d. (*) Fault actions shown are default values specified by the OEM.

101 DFC PROBABLE FAULT FAULT ACTION * CORRECTIVE ACTION FIRST CHECK 715 LSDFault CrankDisable _ Crank Disable Fault, signal has opened or shorted to ground or power or defective crank disable relay None N/A 717 LSDFault LockOff _ Fuel lock off Valve Fault, signal has opened or shorted to ground or power or defective Fuel lock off valve TurnOnMil Check fuel lock off valve for an open wire or connector being disconnected or signal shorted to GND Lockoff Pin B (signal) to SECM Pin A11 Lockoff Pin A (power) to SECM (DRVP) Pin A23 Check CSV for an open coil by disconnecting the CSV connector and measuring the resistance (~26Ω ± 3Ω) 718 LSDFault MIL _ Malfunction Indicator Lamp Fault, signal has opened or shorted to ground or power or defective MIL lamp None Check MIL lamp for an open wire or short to GND.

721 (72) GasFuelAdaptRangeLo In LPG mode, system had to adapt rich more than expected TurnOnMil Check for vacuum leaks. Check fuel trim valves, e.g. leaking valve or hose Check for missing orifice(s). 731 (73) GasFuelAdaptRangeHi In LPG mode, system had to adapt lean more than expected TurnOnMil Check fuel trim valves, e.g. plugged valve or hose. Check for plugged orifice(s). 741 (74) GasO2NotActive Pre-catalyst O2 sensor inactive on LPG, open O2 sensor signal or heater leads, defective O2 sensor (1) TurnOnMil (2) DisableGas O2Ctrl Check that Pre-catalyst O2 sensor connections are OK.

O2 (signal) Pin 3 to SECM Pin B13 O2 Pin 2 (HEATER GND) to SECM (DRVG GNG) Pins A16, B17 O2 Pin 1 (HEATER PWR) to SECM (DRVP + 12V) Pin A23 Verify O2 sensor heater circuit is operating by measuring heater resistance (2.1Ω ± 0.4Ω) O2 Pin 2 (HEATER GND) to Pin 1 (HEATER PWR)