Operation Section Table a.
MI-04 Diagnostic Fault Codes (Flash Codes) 86 DFC Probable Fault Action Corrective Action, First Check 56 XDRPSensorInputHigh +5VDC Transducer power supplied by the SECM to the sensors is above +5.20VDC Engine Shutdown Measure transducer power at the TMAP connector with a multimeter Verify transducer power at the SECM with a multimeter Verify transducer power at ETC with a multimeter Verify transducer power to the foot pedal with a multimeter 57 Engine OverSpeed Engine RPM increased beyond maximum RPM set point Engine Shutdown Usually associated with additional ETC faults z Check for ETC Sticking or other ETC faults z Verify if the lift truck was motored down a steep grade 61 Pedal1SensorInputLo APP1 signal disconnected, open circuit or sensor malfunction (Expected faults when APP connector is unplugged CODES:
61 & 66) MIN Power Limit Check foot pedal connector 62 Pedal1SensorInputHi APP1 sensor failure or shorted circuit MIN Power limit Check foot pedal connector 63 Pedal1SensorRangeLo APP1 potentiometer malfunction. Improper APP1 reading may be due to dirt or oxidation on the sensor traces. Stored Fault Code (MIL Only) Check foot pedal connector 64 Pedal1SensorRangeHi APP1 potentiometer malfunction. Improper APP1 reading may be due to dirt or oxidation on the sensor traces Stored Fault Code (MIL Only) Check foot pedal connector