Doosan — Doosan D60S-5 and G60S-5 Lift Truck Operation Manual

Operation Section Table a. MI-04 Diagnostic Fault Codes (Flash Codes) 87 DFC Probable Fault Action Corrective Action, First Check 65 Pedal2SensorInputLo APP2 sensor failure or shorted circuit MIN power Limit Check foot pedal connector 66 Pedal2SensorInputHi APP2 signal disconnected, open circuit or sensor malfunction (Expected faults when APP connector is unplugged CODES: 61 & 66) MIN power Limit Check foot pedal connector 67 Pedal2SensorRangeLo APP2 potentiometer malfunction. Improper APP2 reading may be due to dirt or oxidation on the sensor traces. Stored Fault Code (MIL Only) Check foot pedal connector 68 Pedal2SensorRangeHi APP2 potentiometer malfunction.

Improper APP2 reading may be due to dirt or oxidation on the sensor traces. Stored Fault Code (MIL Only) Check foot pedal connector 69 Pedal1ToPedal2Difference Measured APP2 pedal position signal is different than APP1 signal MIN power Limit Check foot pedal connector 71 AFRTrimValveOutput FTV modulation driver signal fault (G643E only) Stored Fault Code (MIL, Disable Adaptive learns) Check FTV for an open wire or FTV connector being disconnected