Doosan — Doosan D60S-5 and G60S-5 Lift Truck Operation Manual

Operation Section Table a. MI-04 Diagnostic Fault Codes (Flash Codes) 88 DFC Probable Fault Action Corrective Action, First Check 72 AFRTrimValveLowerDC FTV duty cycle at lower (lean) limit (G643E only) Stored Fault Code (MIL, Disable Adaptive learns) Engine measured Air/Fuel ratio at the O2 sensor is excessively lean. If LP fuel in LP tank is not enough, this fault code can be set. If LP tank is frozen, this fault code can be set, too. It is not system trouble.

z Check for intake manifold leaks z Check balance line (vacuum hose) connection at the regulator z Check N-CA55-500-TR mixer for heavy end build-up and operation (see mixer section) z Check N2001 secondary for operation or low primary pressure (see N2001 Regulator section) 73 AFRTrimValveUpperDC FTV duty cycle at high (rich) limit (Expected fault when FTV connector is unplugged) (G643E only) Stored Fault Code (MIL, Disable Adaptive learns) Engine measured Air/Fuel ratio at the O2 sensor is excessively rich Check FTV connector wiring for an open circuit z Check N-CA55-500-TR mixer for heavy end build-up and operation (see mixer section) z Check N2001 secondary for operation (see N2001 Regulator section)