Komatsu — CLSS

STRUCTURE AND FUNCTION CLSS 2) Introduction of LS pressure Function LS pressure P LS is the actuator load pressure at the outlet port end of the control valve. Actually, it brings the upstream pressure of the pressure compensation valve (the downstream pressure of the spool meter-in) inside spool (3) and sends it to LS shuttle valve (2). When this happens, LS circuit P LS is interconnected with actuator circuit A through check valve (4), and LS pressure P LS = actuator load pressure. In addition, intake hole a of spool (3) and hole c at the tip of LS shuttle valve (2) are designed as small diameter holes to give them a throttling function.

Operation When spool (3) is operated, pump discharge pressure Pp starts to flow to actuator circuit A . First, this pump discharge pressure Pp passes through intake hole a of spool (3) and goes to LS circuit P LS . When the pump discharge pressure Pp rises and actuator circuit pressure A also rises to the necessary pressure, check valve (4) inside spool (3) opens and high pressure of LS circuit P LS flows to actuator circuit A . In this way, LS pressure P LS becomes almost the same pressure as actuator circuit pressure A . 1. Pressure compensation valve 2. LS shuttle valve 3. Spool 4. Check valve Pp : Pump circuit (pressure) A : Actuator circuit (pressure) P LS :LS circuit (pressure) 10-75