STRUCTURE AND FUNCTION CLSS 3. When the control valve is being operated and the demand flow for the actuator becomes greater than the pump discharge from the minimum swash plate angle, the flow of the oil out to tank circuit T is cut off, and all of pump discharge amount Q flows to the actuator circuit. Operation Control valve operated When the control valve is operated to a bigger stroke, LS pressure P LS is generated and acts on the right end of spool (4). When this hap- pens, the area of the opening of the control valve spool is large, so the difference between LS pressure P LS and pump discharge pressure Pp is small.
For this reason, the differential pressure be- tween pump discharge pressure Pp and LS pressure P LS does not reach the load of spring (3) (2.45 MPa (25 kg/cm 2 )), so spool (4) is pushed to the left by spring (3). As a result, pump circuit Pp and tank circuit T are shut off, and all the pump discharge amount Q flows to the actuator circuit. 1. Unload valve 2. Sleeve 3. Spring 4. Spool Pp : Pump circuit (pressure) P LS :LS circuit (pressure) T : Tank circuit (pressure) 10-74