STRUCTURE AND FUNCTION CLSS 4) Pressure compensation valve Function 1. If the maximum load pressure is generated during individual operations or compound operations, and the load pressure becomes higher than other actuators, this acts as a load check valve to prevent the oil in the circuit from flowing back. Operation If pump discharge pressure Pp and LS pres- sure P LS become lower than actuator circuit pressure A , shuttle valve (4) inside pressure compensation valve (1) moves to the left in the direction of the arrow, and connects actuator circuit A and the spring chamber.
When this happens, the movement of piston (3) becomes free, so piston (3) is pushed to the right in the direction of the arrow by spring (2). As a result, valve (5) is also pushed to the right in the direction of the arrow by piston (3), closes pump outlet port circuit P PA , and prevents the oil from flowing back from actuator circuit A to pump outlet port circuit P PA . 1. Pressure compensation valve 2. Spring 3. Piston 4. Shuttle valve 5. Valve Pp : Pump circuit (pressure) P PA :Pump outlet port circuit (pressure) P LS : LS circuit (pressure) A : Actuator circuit (pressure) T : Tank circuit (pressure) 10-77