STRUCTURE AND FUNCTION CLSS 6) Surface area ratio of pressure compensation valve Function The pressure compensation valve determines the compensation characteristics by carrying out fine adjust- ment of the area ratio ( A2/A1 ) between area A2 of piston (3) and area A1 of valve (4) to match the charac- teristics of each actuator. Area ratio (A2/A1) and compensation characteristics When ratio is 1.00: spool meter-in downstream pressure P PB = Max. load pressure B , and oil flow is divided in proportion to area of opening of spool. When ratio is more than 1.00: spool meter-in downstream pressure P PB > Max.
load pressure B , and oil flow is divided in a proportion less than area of opening of spool. When ratio is less than 1.00: spool meter-in downstream pressure P PB B , and oil flow is divided in a proportion more than area of opening of spool. # Spool meter-in downstream pressure P PB acts on area A1 of valve (4), and max. load pressure B (=LS pressure P LS ) acts on area A2 of piston (3). Area ratio of each pressure compensation valve 1. Pressure compensation valve 2. Spring 3. Piston 4. Valve 5. Spool A1 : Cross-sectional area of valve A2 : Cross-sectional area of piston B : Actuator circuit (pressure) Pp :
Pump circuit (pressure) P PB :Spool meter-in upstream pressure 10-81 Valve PortA PortB Remarks Service 1.00 1.00 Bucket DUMP 1.00 CURL 1.00 Arm OUT 0.96 IN 0.98 Boom RAISE 0.96 LOWER 1.00 Travel FOR- WARD 1.00 RE- VERSE 1.00 Throttleø0.6, withoutshuttlevalve Stabilizer RAISE 1.00 LOWER 1.00 Swing LEFT 0.98 RIGHT 0.98 Throttleø0.6