STRUCTURE AND FUNCTION WORK EQUIPMENT - SWING PPC VALVE OPERATION 1) At neutral Ports A and B of the control valve and ports P1 and P2 of the PPC valve are connected to drain chamber D through fine control hole " f " in spool (1). (Fig.1) 2) During fine control (neutral fine control) When piston (4) starts to be pushed by disc (5), retainer (9) is pushed; spool (1) is also pushed by metering spring (2), and moves down.
When this happens, fine control hole " f " is shut off from drain chamber D , and at almost the same time, it is connected to pump pressure chamber Pp , so pilot pressure oil from the pres- sure reducing valve passes through fine control hole " f " and goes from port P1 to port A . When the pressure at port P1 becomes higher, spool (1) is pushed back and fine control hole " f " is shut off from pump pressure chamber Pp . At almost the same time, it is connected to drain chamber D to release the pressure at port P1 . When this happens, spool (1) moves up or down so that the force of metering spring (2) is balanced with the pressure at port P1 .
The rela- tionship in the position of spool (1) and body (10) (fine control hole " f " is at a point midway between drain hole D and pump pressure chamber Pp ) does not change until retainer (9) contacts spool (1). Therefore, metering spring (2) is compressed proportionally to the amount on movement of the control lever, so the pressure at port P1 also rises in proportion to the travel of the control le- ver. In this way, the control valve spool moves to a position where the pressure in chamber A (the same as the pressure at port P1 ) and the force of the control valve spool return spring are bal- anced. (Fig.2) 10-112