STRUCTURE AND FUNCTION WORK EQUIPMENT - SWING PPC VALVE 3) During fine control (when control lever is re- turned) When disc (5) starts to be returned, spool (1) is pushed up by the force of centering spring (3) and the pressure at port P1 . When this happens, fine control hole " f " is con- nected to drain chamber D and the pressure oil at port P1 is released. If the pressure at port P1 drops too far, spool (1) is pushed down by metering spring (2), and fine control hole " f " is shut off from drain chamber D.
At almost the same time, it is connected to pump pressure chamber Pp , and the pump pressure is supplied until the pressure at port P1 recovers to a pressure that corresponds to the lever position. When the spool of the control valve returns, oil in drain chamber D flows in from fine control hole "f" in the valve on the side that is not working. The oil passes through port P2 and enters chamber B to fill the chamber with oil. (Fig.3) 4) At full stroke When disc (5) pushes down piston (4), and re- tainer (9) pushes down spool (1), fine control hole " f " is shut off from drain chamber D , and is connected with pump pressure chamber Pp .
Therefore, the pilot pressure oil from the pres- sure reducing valve passes through fine control hole " f " and flows to chamber A from port P1 , and pushed the control valve spool. The oil returning from chamber B passes from port P2 through fine control hole " f " and flows to drain chamber D . (Fig.4) 10-113