Komatsu — ENGINE CONTROL SYSTEM

STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM Lifting operation (L/O) mode Matching point in lifting operation mode: 45% partial output point. When the lifting operation mode is selected, the engine speed is automatically lowered to the partial position. The cut-off function is cancelled and also the relief pressure is increased. In this condition, control is carried out in the same way as for the general operation and fin- ishing operation modes to match the load on the pump. In this way, the fuel consumption is reduced and the fine control ability is improved. Breaker operation (B/O) mode Matching point in breaker operation mode: 65% partial output point.

The pump absorption torque in the breaker op- eration mode is the same as for the general op- eration and finishing operation modes, and is controlled to become an even lower speed. As a result, the pump absorption torque needed to ensure the breaker drive is ensured, and the engine is used in a range that provides a much better fuel consumption ratio than for the gen- eral operation mode or finishing operation mode. Camshell control is at full flow in B/O mode only. 10-141 Lifting operation (L/O) 33 kW (45 PS) 1450 rpm Breaker operation (B/O) 48 kW (65 PS) 1570 rpm