Komatsu — TABLE OF JUDGEMENT STANDARD VALUE

TESTING AND ADJUSTING TABLE OF JUDGEMENT STANDARD VALUE Machine model PW130-6 20-6 Cate- gory Item Measurement conditions Unit Standard Permissible value value Swing Hydraulic drift of swing • Engine stopped • Hydraulic oil temperature: 45-55°C • Set machine on 150 slope, and set upper structure at 900 to the side. • Make match marks on swing circle outer race and track frame. • Measure distance that match marks move apart after 15 minutes. mm 0 0 Leakage from swing motor • Engine at high idling • Hydraulic oil temperature: 45-55°C • Swing lock switch ON • Relieve swing circuit. l /mm 3 6 Travel Travel speed • Engine at high idling • Hydraulic oil temperature:

45-55°C • In H/O mode • Run up for at least 200 m, and measure time taken to travel next 50m on flat ground. Lo sec. 30 KPH SPEC. 20 KPH SPEC. 30 KPH SPEC. 20 KPH SPEC. 51.5 66.7 45.5-57.5 60.7-72.7 Mi 18 22.5 15-21 19.5-25.5 Hi 6 9 5.8-6.2 8.6-9.4 Hydraulic drift of travel • Engine stopped • Hydraulic oil temperature: 45-55°C • Stop machine on 120 slope • Apply park brake • Measure the distance the machine moves in 5 minutes. mm 0 0