TESTING AND ADJUSTING TABLE OF JUDGEMENT STANDARD VALUE Machine model PW130-6 Cate- gory Permissible value Work equipment Max. 3 15 50 20-9 Item Measurement conditions Unit Standard value Time lag Bucket • Stop bucket and measure time taken for bucket to stop at bottom and then start again • Engine at low idling • Hydraulic oil temperature: 45-55°C sec. Max.2 Internal leakage Cylinders • Hydraulic oil temperature: 45-55°C • Engine at high idling • Relieve circuit to be measured cc/min Max. 3.5 Center swivel joint 10