Komatsu — TABLE OF JUDGEMENT STANDARD VALUE

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS 20-10 Cate- gory Discharge amount of main piston pump (in heavy-duty operation mode) • Pump speed: At 2,000 rpm, PC-EPC current 400 mA Testpump Standardvaluefor Judgement Averagepressure Checkpoint dischargepressure dischargeamount standard (kg/cm2) (kg/cm2) Q(l/min.) Q(l/min.) Asdesired P1 P1 Seegraph Seegraph # The error is large near the point where the graph curves, so avoid measuring at this point.

# When measuring with the pump mounted on the machine, if its is impossible to set the engine speed to the specified speed with the fuel control dial, take the pump discharge amount and the engine speed (same as pump speed) at the point of measurement, and use them as a base for calculating the pump discharge amount at the specified speed. Testpump dischargepressure (kg/cm2) Averagepressure (kg/cm2) Standardvaluefor dischargeamount Q(l/min.) Judgement standard Q(l/min.) P1 P1 Seegraph Seegraph