TESTING AND ADJUSTING TABLE OF JUDGEMENT STANDARD VALUE Flow control characteristics of PC-EPC valve (STD) # The values in this table are used as reference values when carrying out troubleshooting. Cate- gory PW130-6 Performance in compound operations 4.0 20-11 Item Measurement conditions Unit Time taken for swing for boom RAISE + starting swing • Engine at high idling • Hydraulic oil temperature: 45-55°C • In H/O mode • Load the bucket with the rated load and measure the time taken from the position of starting the swing to the point of passing the 90° position. sec.