Komatsu — STANDARD VALUE TABLE FOR ELECTRICAL PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-12 Sys- tem Name of component Connector No. Inspec- tion method Judgement table Measurement conditions Control system Fuel control dial E06 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 0.25 - 7 kΩ Between (2) - (3) 0.25 - 7 kΩ Between (1) - (3) 4 - 6 kΩ 1) Turn starting switch OFF. 2) Disconnect connector.

Governor motor Potentiometer E04 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 0.25 - 7 kΩ Between (2) - (3) 0.25 - 7 kΩ Between (1) - (3) 4 - 6 kΩ 1) Turn starting switch OFF. 2) Disconnect connector. Motor E05 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 2.5 - 7.5 kΩ Between (3) - (4) 2.5 - 7.5 kΩ Between (1) - (3) No continuity Between (1) - chassis No continuity Between (3) - chassis No continuity 1) Turn starting switch OFF. 2) Disconnect connector.

Engine speed sensor E07 Measure resistance If the condition is as shown in the table below, it is normal Between (male) (1) - (2) 500 - 1,000 Ω Between (male) (2) - chassis Min. 1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector. Measure voltage Measure with AC range Between (1) - (2) 0.5 - 3.0 V 1) Start engine. 2) Insert T- adapter. Adjust 1) Screw in the speed sensor until it contacts the ring gear, then turn back 1 ± 1/6 turns. 2) It must work normally when adjusted as above.

PPC pressure switch Left swing S08 Right swing S10 Bucket DUMP S07 Bucket CURL S06 Arm OUT S03 Arm IN S05 Boom LOWER S04 Boom RAISE S02 2p Boom RETRACT S11 2p Boom EXTEND S12 Stabilizer UP S14 Stabilizer DOWN S13 Service S09 Service G72 Travel (auto susp. lock) G132 Travel (auto DECEL) G75 Measure resistance If the condition is as shown in the table below, it is normal Between Levers at neutral Min. 1 MΩ (male) (1) - (2) Lever operated Max. 1Ω Between (male) (1), (2) - chassis Min. 1 MΩ 1) Start engine (or with accumulator charged if engine is stopped) 2) Disconnect connectors.

Between (1) - (2) 0.25 - 7 kΩ Between (2) - (3) 0.25 - 7 kΩ Between (1) - (3) 4 - 6 kΩ Between (1) - (2) 0.25 - 7 kΩ Between (2) - (3) 0.25 - 7 kΩ Between (1) - (3) 4 - 6 kΩ Between (1) - (2) 2.5 - 7.5 kΩ Between (3) - (4) 2.5 - 7.5 kΩ Between (1) - (3) No continuity Between (1) - chassis No continuity Between (3) - chassis No continuity Between (male) (1) - (2) 500 - 1,000 Ω Between (male) (2) - chassis Min. 1 MΩ Between (1) - (2) 0.5 - 3.0 V Between (male) (1) - (2) Levers at neutral Min. 1 MΩ Lever operated Max. 1Ω Between (male) (1), (2) - chassis Min. 1 MΩ