TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-13 Sys- tem Name of component Connector No. Inspec- tion method Judgement table Measurement conditions Control system Pump pressure sensor C08 Measure voltage If the condition is as shown in the table below, it is normal Between (2) - (1) 18-27 V Between All levers at neutral 0.5 - 1.5 V (3) - (1) At arm IN relief 3.1 - 4.5 V 1) Start engine. 2) Turn fuel control dial to MAX position. 3) Insert T-adapter. Swing lock switch X05 (female) Measure resistance If the condition is as shown in the table below, it is normal Between When switch is OFF Min. 1MΩ (1) - (2) Between (1) - (2) When switch is ON Max.
1 Ω 1) Turn starting switch OFF. 2) Disconnect connector C02. PC-EPC solenoid valve C13 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 7 - 14 Ω Between (1), (2) - chassis Min. 1 MΩ 1) Turn pump prolix switch OFF. 2) Turn starting switch OFF. 3) Disconnect connector C13. Swing holding brake solenoid valve V04 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector V04.
Travel speed solenoid valve V06 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector V06. 2-stage relief solenoid valve V05 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector V05. Suspension lock solenoid valve G25 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min.
1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector G25. LS-EPC solenoid valve C10 (male) Measure resistance If the condition is as shown in the table below, it is normal Between (1) - (2) 7 - 14 Ω Between (1), (2) - chassis Min. 1 MΩ 1) Turn starting switch OFF. 2) Disconnect connector C10. Between (2) - (1) 18-27 V Between (3) - (1) All levers at neutral 0.5 - 1.5 V At arm IN relief 3.1 - 4.5 V Between (1) - (2) Between (1) - (2) When switch is OFF Min. 1MΩ When switch is ON Max. 1 Ω Between (1) - (2) 7 - 14 Ω Between (1), (2) - chassis Min. 1 MΩ Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min.
1 MΩ Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ Between (1) - (2) 20 - 60 Ω Between (1), (2) - chassis Min. 1 MΩ Between (1) - (2) 7 - 14 Ω Between (1), (2) - chassis Min. 1 MΩ