Komatsu — STANDARD VALUE TABLE FOR ELECTRICAL PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-20 Name of component Connector No. Inspec- tion method Judgement table Measurement conditions Alternator Between alternator terminal R and chassis Measure voltage If the condition is as shown in the table below, When engine is running (1/2 throttle or above)  27.5 - 29.5 V # If the battery is old, or after starting in cold areas, the voltage may not rise for some time. 1) Start engine. Gauges Position of gauge Display level resistance (KO) display (Monitor panel input resistance) Starting switch ON Starting switch OFF Min. - Max.

Right side All OFF (15) - 0.646 14 0.575 - 3.420 Measure 13 3.156 - 3.708  resistance 12 3.422 - 3.804 between coolant 11 3.512 - 3.900 temperature 10 3.600 - 4.125 gauge C03 Display 9 3.807 - 4.349 (female) position 8 4.015 - 5.122 (1) - C03 (female) 7 4.728 - 5.899 (16) 6 5.445 - 6.818 5 6.294 - 7.910  4 7.302 - 9.210 3 8.502 - 10.774 2 9.946 - 36.535 Left side 1 33.725 - # Levels 13, 14 flash 1) Insert a dummy resistance with the starting switch OFF, or measure the resistance of the sensor. 2) Check the display with the starting switch ON. Position of gauge Display level resistance (KO) display (Monitor panel input resistance) Starting switch ON Starting switch OFF Min. - Max.

Right side 14 - 13.82 13 11.71 - 17.43 Measure 12 15.18 - 21.25 resistance 11 18.90 - 25.05  between fuel level 10 22.59 - 28.45 gauge C03 9 25.82 - 31.85 (female) (2) 8 29.18 - 35.22 - chassis Display position 7 32.45 - 39.91 6 37.00 - 44.60 5 41.77 - 48.72 4 45.52 - 55.14 3 50.42 - 64.35  2 60.61 - 77.07 1 72.98 - 691.5 All OFF 638.00 - Left side (0) # Levels 13, 14 flash 1) Insert a dummy resistance with the starting switch OFF, or measure the resistance of the sensor. 2) Check the display with the starting switch ON.

Position of gauge display Display level resistance (KO) (Monitor panel input resistance) Starting switch ON Starting switch OFF Measure resistance between coolant temperature gauge C03 (female) (1) - C03 (female) (16) Right side All OFF (15) 14  13 12 11 10 Display 9 position 8 7 6 5  4 3 2 Left side 1 Min. - Max.

- 0.646 0.575 - 3.420 3.156 - 3.708 3.422 - 3.804 3.512 - 3.900 3.600 - 4.125 3.807 - 4.349 4.015 - 5.122 4.728 - 5.899 5.445 - 6.818 6.294 - 7.910 7.302 - 9.210 8.502 - 10.774 9.946 - 36.535 33.725 - Position of gauge display Display level resistance (KO) (Monitor panel input resistance) Starting switch ON Starting switch OFF Measure resistance between fuel level gauge C03 (female) (2) - chassis Right side 14 13 12 11  10 9 8 Display position 7 6 5 4 3  2 1 All OFF Left side (0) Min. - Max. - 13.82 11.71 - 17.43 15.18 - 21.25 18.90 - 25.05 22.59 - 28.45 25.82 - 31.85 29.18 - 35.22 32.45 - 39.91 37.00 - 44.60 41.77 - 48.72 45.52 - 55.14 50.42 - 64.35 60.61 - 77.07 72.98 - 691.5 638.00 -