TESTING AND ADJUSTING STANDARD VALUE TABLE FOR ELECTRICAL PARTS 20-19 Sys- tem Name of component Connector No. Inspec- tion method Judgement table Measurement conditions Monitor Engine oil pressure sensor P10 (male) Measure resistance If the condition is as shown in the table below, it is normal Low pressure sensor Pressure Opens at 0.110 ± 0.014 MPa rising (Non continuity) (1.12 ± 0.14 kg/cm2) Pressure Closes at 0.08 ± 0.014 MPa dropping (Continuity) (0.85 ± 0.14 kg/cm2) Sensor connector 1) Install oil pressure measuring gauge. 2) Remove wiring harness terminal. 3) Start engine. 4) Put tester in contact between sensor terminals A & C.
Fuel level sensor P06 (male) Measure resistance If the condition is as shown in the table below, it is normal Raise float Approx. to stopper 12 Ω or below Lower float Approx. to stopper 85 - 110 Ω 1) Turn starting switch OFF. 2) Disconnect connector P06. 3) Drain fuel, then remove sensor. 4) Insert T-adapter into sensor. # Connect the T- adapter to the connector and sensor flange. Air cleaner clogging sensor P11 P12 Measure resistance If the condition is as shown in the table below, it is normal Air cleaner normal Continuity Air cleaner clogged No continuity 1) Start engine. 2) Disconnect P11, P12. 3) Put tester in contact with connector at sensor end to measure.
Pressure rising Opens at 0.110 ± 0.014 MPa (Non continuity) (1.12 ± 0.14 kg/cm2) Pressure dropping Closes at 0.08 ± 0.014 MPa (Continuity) (0.85 ± 0.14 kg/cm2) Raise float to stopper Approx. 12 Ω or below Lower float to stopper Approx. 85 - 110 Ω Air cleaner normal Continuity Air cleaner clogged No continuity