TESTING AND ADJUSTING TESTING AND ADJUSTING LS VALVE OUTPUT PRESSURE (SERVO PISTON INPUT PRESSURE) AND LS DIFFERENTIAL PRESSURE 3. Adjusting LS valve When the differential pressure is measured under the conditions above, and the results show that the differ- ential pressure is not within the standard value, adjust as follows. 1) Loosen locknut (4) and turn screw (5) to adjust the differential pressure. Turn the screw to adjust as follows. To INCREASE pressure, turn CLOCKWISE. To DECREASE pressure, turn COUNTERCLOCKWISE. # Amount of adjustment for one turn of screw: 1.3 MPa {13.3 kg/cm 2 } 2) After adjusting, tighten locknut (4). Locknut: 56.4 ± 7.4 Nm {5.75 ± 0.75 kgm} Note :
Always measure the differential pressure while adjusting. 20-32