Komatsu — BLEEDING AIR

TESTING AND ADJUSTING BLEEDING AIR 2. Bleeding air from hydraulic cylinders 1) Start the engine and run at idling for approx. 5 minutes. 2) Run the engine at low idling, then raise and lower the boom 4 - 5 times in succession. # Operate the piston rod to approx. 100 mm before the end of its stroke. Do not relieve the circuit under any circumstances. 3) Run the engine at full throttle and repeat Step 2). After that, run the engine at low idling, and oper- ate the piston rod to the end of its stroke to relieve the circuit. 4) Repeat Steps 2) and 3) to bleed the air from the arm and bucket cylinders. # When the cylinder has been replaced, bleed the air before connecting the piston rod.

Be particularly careful not to operate the cylinder to the end of its stroke when the piston rod has been connected to the LOWER end of the boom cylinder. 3. Bleeding air from swing motor 1) Lock the swing lever and run at idling for 5 min- utes. # The system is designed so that the pressure at port S carries out the air bleeding. 2) Disconnect hose (1) of the swing motor and fit a blind plug in the hose. 3) Run the engine at low idling, and check that oil oozes out from elbow (2). # If no oil oozes out from the elbow, carry out Step 1) again. 4) Connect hose 91). hose: 137.3 ± 29.4 Nm {14 ± 3.0 kgm} 4. Bleeding air from travel motor 1) Disconnect motor drain hose (2).

2) Run t he engine at low idling and check that oil oozes out from the nipple. 3) If oil oozes out, connect hose (2). 20-48