TESTING AND ADJUSTING ACCUMULATORS OPERATING INSTRUCTIONS 1. Gas charging pressures The critical value of gas pre-charge for accumulator 20E-60K1150 is as follows. (Ratio between maximum working pressure and gas pre-charge pressure.) 20E-60K1150 Max working pressure (P2) = 210 bar Gas pre-charge (P0) = 50 bar Permissible pressure ratio P2 : P0 = 8 : 1 If gas pre-charge falls below this ratio then it becomes "Critical". 2. Temperature effect to be taken into account In order not to exceed the stated temperatures, the pre-charge pressure P0 has to be determined at charging temperature: t0 + 273 p0,t0 = p0.t2 t2 + 273 t0 = pre-charge temperature (0C) t2 = max. operating temperature (0C) 3.

PREPARATION Prior to each testing, charging or topping-up of nitro- gen, the accumulator has to be separated from the pressurized system by means of the shut-off valve and the fluid has to be released. The protective cap S has to be unscrewed. Slightly loosen the int. hex. screw by means of an Allen key GW 0, DIN 911 (approx. 1/2 turn). Screw cap nut D by hand onto accu- mulator gas valve. Turn charging unit to a position where the gauge can be easily read. 4. TESTING Valve V is opened by loosening the int. hex. screw with spindle A . After the pointer of the gauge begins to deflect unscrew the spindle by a further full turn. The gauge now shows the charging pressure in the accumulator.

The check valve prevents any escape of nitrogen. 5. PRESSURE RELEASE By carefully opening relief valve B , the nitrogen es- capes into the atmosphere. 6. PRESSURE INCREASE (CHARGING) Use only nitrogen for charging accumulators. Never use oxygen! Danger of explosion! If the gas pressure in the nitrogen bottle is higher than the max. operating pressure of the accumulator, a pressure re- lease valve and a gas safety valve must be fitted. 20-50