TROUBLESHOOTING POINTS TO REMEMBER WHEN CARRYING OUT MAINTENANCE Connecting connectors Check the connector visually. 1) Check that there is no oil, dirt, or water stuck to the connector pins (mating portion). 2) Check that there is no deformation, defective contact, corrosion, or damage to the connec- tor pins. 3) Check that there is no damage or breakage to the outside of the connector. # If there is any oil, water, or dirt stuck to the connector, wipe it off with a dry cloth. If any water has got inside the connector warm the inside of the wiring with a dryer, but be care- ful not to make it too hot as this will cause short circuits.
# If there is any damage or breakage, replace the connector. Fix the connector securely. Align the position of the connector correctly, then insert it securely. For connectors with lock stopper, push in the con- nector until the stopper clicks into position. Correct any protrusion of the boot and any mis- alignment of the wiring harness For connectors fitted with boots, correct any pro- trusion of the boot. In addition, if the wiring har- ness is misaligned, or the clamp is out of position, adjust it to its correct position. # If the connector cannot be corrected easily, remove the clamp and adjust the position.
If the connector clamp has been removed, be sure to return it to its original position. Check also that there are no loose clamps. 20-59