Komatsu — DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL

TROUBLESHOOTING TESTING AND ADJUSTING DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL Operation Display 4. To finish with the trouble data display mode, keep the time switch + L.H. travel speed switch pressed for 2.5 seconds. 4) If there is no abnormality code in memory 5. To erase the memory, press the time switch, turn the starting switch from OFF to ON, and keep the time switch pressed for 5 seconds. 3. Machine data monitoring function The input signals from the sensors and the output signals to drive the solenoid are displayed on the time display and service meter display. 1) Method of displaying monitoring code 20-85 Operation 1.

To set to the machine data monitoring mode, keep the time switch + knob button function switch pressed for 2.5 seconds. Note: This is possible at the following times. 1) During the normal mode 2) During the user code display mode 3) During the time adjustment mode 4) During the trouble data display mode 1. On the time display and service meter display, the monitoring code and data are displayed. • Example of display: 1) When engine speed is monitored (monitoring code 10)