Komatsu — DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL

DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL TROUBLESHOOTING TESTING AND ADJUSTING 4) Display of trouble data The monitor panel records both the service codes which are included in the user code and the service codes which are not included. This data can be displayed on the time display as follows. # For details of the service codes that are not included in the user code, see ACTION TAKEN BY CONTROL- LER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE or the JUDGEMENT TABLE. i) Method of displaying trouble data 20-84 Operation Display 1. To set the trouble data display mode, keep the TIMW switch + L.H. travel speed switch pressed for 2.5 seconds. Note:

It is possible to call it up at the follow- ing times. 1) In the normal mode 2) In the user code display mode 3) In the machine data monitoring mode 4) In the time adjustment mode 2. To go the next service code display, press the time switch + R.H. working mode switch. 3. To go back the previous service code dis- play, press the time switch + L.H. working 1. On the time display and service meter display, the service code and number of hours (service meter hours) that have elapsed since the occurrence of the abnormal- ity are displayed. • Example of display:

When E212 has occurred 12 hours before (on the service meter) 1) Display of service code 2) Display of elapsed time 3) If any abnomality exists at this time, the E mark is displayed.