Komatsu — DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE

TROUBLESHOOTING DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE 4) Check kerosene mode input signal i) Set to the monitoring mode, and display monitoring code 22. ii) Connect the CN-M36 connector and check that bit (5) lights up. 5) Check knob switch input signal. i) Set to the monitoring mode, and display monitoring code 22. ii) Turn the knob switch ON and check that bit (6) lights up. 2. Check output signals 1) Check LS-EPC solenoid output current i) Set to the monitoring mode, and display monitoring code 15. ii) Run the engine at high idling with all the levers at neutral and in the G/O or H/O mode, and measure the current. # All levers at neutral:

800 ± 80 mA Engine at high idling, any lever operated (other than travel): 0 A 2) No. 2 throttle signal i) Set to the monitoring mode, and display monitoring code 16. ii) Use the procedure in item 2 for checking the monitor panel output signal, and measure the engine speed. 3) Checking ON OFF solenoid condition i) Set to the monitoring mode, and display monitoring code 23. ii) Refer to Table 3 and check that the applicable bit lights up. Table 3 Types of solenoid and conditions for actuation. # Operate the lever slightly not enough to move the machine. 4) Check PC-EPC solenoid output current i) Set to the monitoring mode, and display monitoring codes 13 and 14.

ii) With the starting switch kept at the ON position (G/O mode), measure the current when the fuel control dial is turned to the MAX position and auto-decel is OFF. Current with starting switch ON (G/O mode) and fuel control dial at MAX: 650 ± 80 (mA) 20-100 Nameofsolenoid Actuationcondition Bitthatlightsup Swingholdingbrake Swingorworkequipmentleveroperated (3) 2stagerelief Travelleveroperated (5) Travelspeedselector TravelspeedselectorswitchMiorLo (6)