Komatsu — POINTS TO REMEMBER WHEN CARRYING OUT TROUBLESHOOTING OF ENGINE THROTTLE, PUMP CONTROLLER ( GOVERNOR CONTROL SYSTEM)

POINTS TO REMEMBER WHEN CARRYING OUT TROUBLESHOOT- ING OF ENGINE THROTTLE, PUMP CONTROLLER (GOVERNOR CONTROL SYSTEM) TROUBLESHOOTING TESTING AND ADJUSTING POINTS TO REMEMBER WHEN CARRYING OUT TROUBLESHOOTING OF ENGINE THROTTLE, PUMP CONTROLLER (GOVERNOR CONTROL SYSTEM) 1. Points to remember when there is abnormality which is not displayed by user code The engine is controlled by an engine throttle, pump controller. The problems that may occur with this system include the following. 1. Idling speed is too high (too low) 2. High idling speed is to low 3. Auto-deceleration speed is too high (too low) 4. Engine speed for automatic warming-up operation is too high (too low) 5. There is hunting 6.

Engine does not stop If any abnormality occurs, and the abnormality is displayed on the time display portion of the monitor panel, use the troubleshooting table to determine the appropriate troubleshooting flow chart from E1 to E10. How- ever, if there is any abnormality in the machine and no abnormality display is given, it is necessary to determine whether the problem is in the mechanical system or in the electrical system. If the linkage be- tween the governor motor and the injection pump is not properly adjusted, problems 1 to 6 listed above may occur.

Therefore, if there is no abnormality display, but one of problems 1 to 6 listed above has occurred, carry out troubleshooting as follows. YES YES 2 If linkage between governor motor and injection pump is disconnected, does operation of governor motor become normal? Defective adjustment of governor motor likage See TESTING AND ADJUSTING. If linkage between governor motor and injection pump is dis- connected and pump lever is operated by hand or is fixed with wire, does condition return to normal? 1 NO Go to troubleshooting E-9 - E-12 of elec- trical system With starting switch at ON, operate fuel control dial and wor- king mode switch.

Go to troubleshooting S-1 - S-16 of en- gine system NO If engine does not stop, push governor lever to STOP position and check if engine stops. Disconnect the linkage as explained above, or check the adjustment and go to the troubleshooting flow chart for the mechanical system or electrical system. For details of the procedure for adjusting the linkage, see TESTING AND ADJUSTING. 2. Points to remember if abnormality returns to normal by itself In the following cases, there is a high probability that the same problem will occur again, so it is desirable to follow up this problem carefully.

1) If any abnormality returns to normal by itself, or 2) If the connector is disconnected and the T-adapter is inserted, or if the T-adapter is removed and the connector is returned to its original position when carrying out troubleshooting of the failure, and the service code is no longer displayed, or if the monitor display returns to normal. 3) After completing troubleshooting, always erase the service code from memory. 3. User code memory retention function When displaying the abnormality code in memory and carrying out troubleshooting, not down the content of the display, then erase the display.

After trying to re-enact the problem, carry out troubleshooting according to the failure code that is displayed. (There are cases where mistaken operation or abnormalities that occur when the connector is discon- nected are recorded by the memory retention function. Erasing the data in this way saves any wasted work.) 20-107