Komatsu — ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE

TROUBLESHOOTING TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-108 User code Service code Abnormal system Nature of abnormality E05 E308 E308 Abnormality in fuel control dial input value 1. Short circuit in wiring harness between C03 (7) - (14), (7) - (17), (14) - (17) 2. Short circuit in wiring harness between E04 (1) - (2), (1) - (3), (2) - (3) 3. Short circuit in wiring harness between E06 (1) - (2), (1) - (3), (2) - (3) 4. Short circuit in wiring harness between C03 (7) - (4), (4) - (17) 5. Disconnection in wiring harness between C03 (7) - X07, (6) - E06 (1) 6.

Disconnection in wiring harness between C03 (4) - X07, (5) - E06 (2) 7. Disconnection in wiring harness between C03 (17) - X07, (4) - E06 (3) 8. Defective fuel control dial 9. Defective contact of C03, X07, E06 connectors 1. Disconnection inside governor motor 2. Disconnection in wiring harness between C02 (2) - E05 (1) 3. Disconnection in wiring harness between C02 (4) - E05 (3) 4. Disconnection in wiring harness between C02 (3) - E05 (2) 5. Disconnection in wiring harness between C02 (5) - E05 (4) 6. Defective contact of E05 connector E317 Abnormality (disconnec- tion) in motor drive system E318 Abnormality (short circuit) in motor drive system 1. Short circuit inside governor motor 2.

Wiring harnesses between C02 (2) - E05 (1), and between C02 (4) - E05 (3) short circuiting with wiring harness between C02 (5) - E05 (2) 3. Wiring harnesses between C02 (4) - E05 (3), and between C02 (2) - E05 (1) short circuiting with wiring harness between C02 (5) - E05 (4) 4. Wiring harness in Items 2 and 3 short circuiting with ground