Komatsu — ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE

TROUBLESHOOTING TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-109 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality E03 (male) E06 (female) Resistance value (7) - (4) (1) - (2) 0.25 - 7kΩ (4) - (17) (2) - (3) 0.25 - 7kΩ (7) - (17) - 2 - 3 kΩ - (1) - (3) 2 - 3 kΩ Between each pin and chassis - Min. 1 MΩ Maintains engine speed at position of fuel control dial immediately before abnor- mality occurred 1. Does not become partial speed when set at MAX position 2. Does not reach high idling when set at partial speed 3.

There are cases of hunting 4. Lacks output (max. speed of engine is too low) E05 (male) E01 (female) Resistance value (1) - (2) (2) - (3) 0.25 - 7kΩ (3) - (4) (4) - (5) 0.25 - 7kΩ (1) - (3) (2) - (4) Min. 1 MΩ (1) - (4) (2) - (5) Min. 1 MΩ Between pins Between pins (1), (2), (3), (4) (2), (3), (4) and Min. 1 MΩ and chassis (5) and chassis Motor drive current: Hold: 0.7 A Start: 0.84 A Takes no particular action 1. When there is a disconnection in both the A phase and B phase at the same time, the problem is the same as for a short circuit in the governor motor system 2.

When there is a disconnection in only one of A phase or B phase 1) Engine does not stop 2) Stops moving at position immediately before failure, so engine speed cannot be controlled 3) There are cases of hunting E05 (male) E01 (female) Resistance value (1) - (2) (2) - (3) 0.25 - 7kΩ (3) - (4) (4) - (5) 0.25 - 7kΩ (1) - (3) (2) - (4) Min. 1 MΩ (1) - (4) (2) - (5) Min. 1 MΩ Between pins Between pins (1), (2), (3), (4) (2), (3), (4) and Min. 1 MΩ and chassis (5) and chassis Motor drive current: Hold: 0.7 A Start: 0.84 A Sets motor drive current to 0 1. If during operation 1) Sets to low idling 2) Engine does not stop 3) There are cases of hunting 2.

When stopped 1) Engine starts, but stays at low idling 2) Engine does not stop after starting 3) There are cases of hunting E03 (male) E06 (female) Resistance value (7) - (4) (1) - (2) 0.25 - 7kΩ (4) - (17) (2) - (3) 0.25 - 7kΩ (7) - (17) - 2 - 3 kΩ - (1) - (3) 2 - 3 kΩ Between each pin and chassis - Min. 1 MΩ E05 (male) E01 (female) Resistance value (1) - (2) (2) - (3) 0.25 - 7kΩ (3) - (4) (4) - (5) 0.25 - 7kΩ (1) - (3) (2) - (4) Min. 1 MΩ (1) - (4) (2) - (5) Min. 1 MΩ Between pins (1), (2), (3), (4) and chassis Between pins (2), (3), (4) and (5) and chassis Min.

1 MΩ E05 (male) E01 (female) Resistance value (1) - (2) (2) - (3) 0.25 - 7kΩ (3) - (4) (4) - (5) 0.25 - 7kΩ (1) - (3) (2) - (4) Min. 1 MΩ (1) - (4) (2) - (5) Min. 1 MΩ Between pins (1), (2), (3), (4) and chassis Between pins (2), (3), (4) and (5) and chassis Min. 1 MΩ