TROUBLESHOOTING TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-110 User code Service code Abnormal system Nature of abnormality - E306 Abnormality in feedback potentiometer system 1. Short circuit in wiring harness between C03 (7) - (14), (7) - (17), (14) - (17) 2. Short circuit in wiring harness between E04 (1) - (2), (1) - (3), (2) - (3) 3. Short circuit in wiring harness between E06 (1) - (2), (1) - (3), (2) - (3) 4. Short circuit in wiring harness between C03 (7) - (4), (4) - (17) 5. Disconnection in wiring harness between C03 (7) - E04 (1) 6. Disconnection in wiring harness between C03 (14) - E04 (2) 7.
Disconnection in wiring harness between C03 (17) E04 (3) 8. Defective governor motor potentiometer 9. Defective contact of C03, E04 connectors If excess current flows between C03 (1) and battery relay # This occurs only when turning starting switch to OFF order to stop engine - E315 Abnormality (short circuit) in battery relay output system - E316 Abnormality (step-out) in motor 1. Defective adjustment of rod or twisting of loose spring 2. Abnormality in governor motor 3. Abnormality in engine throttle, pump controller