TROUBLESHOOTING TESTING AND ADJUSTING TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-111 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality E05 (male) E01 (female) Resistance value (7) - (4) (1) - (2) 0.25 - 7kΩ (7) - (17) (2) - (3) 0.25 - 7kΩ (14) - (17) - 2 - 3 kΩ - (1) - (3) 4 - 6 kΩ Between each pin and chassis - Min. 1 MΩ Calculated position of motor and carries out control from value of voltage immediately before abnormality occurred 1. Precision of engine speed control may be reduced. For example:
1) Engine does not change to high idling speed (a little too low) 2) Engine does not change to low idling speed (a little too high) 3) Defective engine speed for auto-deceleration or auto- matic warming-up 4) Engine may not stop # The governor motor moves in the direction to stop the engine, but motor may not move completely to the position to stop the engine. 5) There are cases of hunting Between C0(3) (1) and chassis: 20 - 30 V # Hold with the motor in the stop posi- tion for 2 - 2.5 sec, return to the low idling position, then turn the battery relay OFF. Sets battery relay drive current to 0 Engine does not stop 1. Linkage adjustment correct 1.
Displays when return- ing from high idling to low idling # Start again (repeat step-out) 2. In some cases it may not display when returning from partial speed to low idling Engine speed cannot be controlled (particularly at high idling), so there is hunting. 2. Must move lightly when connector is removed 3. Normal E05 (male) E01 (female) Resistance value (7) - (4) (1) - (2) 0.25 - 7kΩ (7) - (17) (2) - (3) 0.25 - 7kΩ (14) - (17) - 2 - 3 kΩ - (1) - (3) 4 - 6 kΩ Between each pin and chassis - Min. 1 MΩ