Komatsu — POINTS TO REMEMBER WHEN TROUBLESHOOTING PUMP CONTROLLER SYSTEM

TESTING AND ADJUSTING POINTS TO REMEMBER WHEN TROUBLESHOOTING PUMP CONTROLLER SYSTEM POINTS TO REMEMBER WHEN TROUBLESHOOTING PUMP CONTROLLER SYSTEM 1. Points to remember if abnormality returns to normal by itself In the following cases, there is a high probability that the same problem will occur again, so it is desirable to follow up the problem carefully.

1) If any abnormality returns to normal by itself, or 2) If the connector is disconnected and the T-adapter is inserted, or if the T-adapter is removed and the connector is returned to its original position when carrying out troubleshooting of the failure, and the service code is no longer displayed, or if the monitor display returns to normal. 3) After completing troubleshooting, always erase the service code from memory. 2. Service code memory retention function When displaying the abnormality code in memory and carrying out troubleshooting, note down all the con- tents of the display, then erase the display.

After trying to re-enact the problem, carry out troubleshooting according to the service code that is displayed. (There are cases where mistaken operation or abnormalities that occur when the connector is discon- nected are recorded by the memory retention function. Erasing the data in this way saves any wasted work.) 20-161