TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-162 User code Service code Abnormal system Nature of abnormality E02 E232 Short circuit in pump PC-EPC solenoid system 1. Internal short circuit, short circuit with chassis ground in pump PC-EPC solenoid 2. Short circuit with power source, short circuit with chassis ground in wiring harness between controller C02 (8) and PC-EPC solenoid C13 (1) ((+) end) 3.
Wiring harness between controller C02 (18) and PC-EPC solenoid C13 (2) ((-) end) short circuiting with power source 4 Defective engine throttle, pump controller E233 Disconnection in pump PC-EPC solenoid system 1. Internal disconnection, defective contact in pump PC-EPC solenoid 2. Defective contact or disconnection in wiring harness between controller C02 (8) and PC-EPC solenoid C13 (1) ((+ end) 3. Short circuit with chassis ground, defective contact or disconnection in wiring harness between controller C02 (18) and PC-EPC solenoid C13 (2) ((-) end) 4. Defective engine throttle, pump controller E02 E203 Short circuit in swing holding brake solenoid system 1.
Internal short circuit, short circuit with chassis ground in swing holding brake solenoid 2. Wiring harness between controller C01 (3) and solenoid V04 (1) ((+) end) short circuiting with chassis ground 3. Defective engine throttle, pump controller E213 Disconnection in swing holding brake solenoid system 1. Internal disconnection, defective contact in swing holding brake solenoid 2. Short circuit with power source, defective contact or discon- nection in wiring harness between controller C01 (3) and solenoid V04 (1) ((+) end) 3. Defective contact or disconnection in wiring harness between solenoid V04 (2) and chassis ground ((-) end) 4. Defective engine throttle, pump controller