Komatsu — ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE

TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-163 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality • Resistance of solenoid: 7 - 14 Ω 1. Makes output to PC-EPC sole- noid 0 2. Displays user code E02 on monitor panel # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) 1.

No current flows to the pump PC- EPC solenoid Therefore, when the load is large, there is a big drop in the engine speed, which may result in the engine stalling. 2. Swing acceleration is poor • Resistance of solenoid: 7 - 14 Ω • Current: 1,000 mA [H/O mode, auto-decele-ration ON, levers at neutral, fuel control dial at MAX.] 1. The current stops flowing to the PC-EPC solenoid, so no particu- lar action is taken. 2. If there is short circuit with chassis ground at (-) terminal, current (1A or more) continues to flow to PC-EPC solenoid 3. Displays user code E02 on monitor panel # If the abnormality is restored by the vibration of the machine, the condition will automatically return to normal.

(However, the service code does not go out.) 1. In the case of 1, it is the same as E232. 2. In the case of 2, current (1A or more) continues to flow to the pump PC-EPC solenoid, so the output pressure of the pump PC- EPC valve increases and the overall speed becomes slower. • Resistance of solenoid: 20 - 60Ω 1. Makes output to solenoid 0 2. Displays user code E03 on monitor panel # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) When the swing is operated, the motor brake is not released, so the upper structure does not swing. • Resistance of solenoid:

20 - 60 Ω 1. The current stops flowing to the solenoid, so no particular action is taken. 2. Displays user code E03 on monitor panel # If the abnormality is restored by the vibration of the machine, the condition will automatically return to normal. (However, the service code does not go out.) Same as E203 display