TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-165 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality • Resistance of solenoid: 20 - 60 Ω 1. Makes output to solenoid 0 # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) 1. When traveling or using the power max. function, the relief pressure is not raised, so there is lack of power.
# When traveling, 2-stage relief solenoid works only on PC120 and 130 • Resistance of solenoid: 20 - 60 Ω 1. Makes output to solenoid 0 # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) Even when travel speed selection is operated, travel speed does not change (remains at Lo) • Resistance of solenoid: 20 - 60 Ω 1. Makes output to solenoid 0 # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) • Resistance of solenoid: 20 - 60 Ω 1.
The current stops flowing to the solenoid, so no particular action is taken. # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) Same as E207 display • Resistance of solenoid: 20 - 60 Ω 1. The current stops flowing to the solenoid, so no particular action is taken. # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) Same as E205 display • Resistance of solenoid: 20 - 60 Ω 1.
The current stops flowing to the solenoid, so no particular action is taken. # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) Same as E206 display