Komatsu — ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE

TESTING AND ADJUSTING ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE 20-167 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality • Between C17 (6) (13) and chassis: Max. 1Ω • Between C17 (5) (7) (14) and chassis: Min. 1Ω Detects abnormality in input 1. Retains data when starting switch is ON 1. Engine stalls, or 2. All work equipment, swing, travel speeds are slow or lack power 1. When communications are impossible with the monitor, controls as follows. (1) Working mode : G/O (2) Priority mode : OFF (3) Travel speed : Lo (4) Auto-deceleration :

ON (5) Power max. : ON (others are as usual) 1. (1) Even when travel is operated, the power does not increase (2) The swift slow-down function does not work (3) The auto-deceleration cannot be canceled (4) The travel speed does not increase (5) The priority mode has no effect (6) The automatic mode has no effect • Resistance of solenoid: 7 - 14 Ω 1. Makes output to LS-EPC solenoid 0 # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) 1. The Lo travel speed is too fast 2. In L/O mode and F/O mode, the work equipment speed is too fast 3.

When the engine is running at low idling, the swing speed is too fast • Current: 705 mA (Levers at neutral, low idling) 1. The current stops flowing to the LS-EPC solenoid, so no particular action is taken. 2. If there is short circuit with chassis ground at (-) terminal, current (1A or more) continues to flow to LS-EPC solenoid # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) 1. In the case of 1, it is the same as E222 2.

In the case of 2, the current (1A or more) continues to flow to the LS- EPC solenoid, so the work equip- ment, travel, and swing speeds are slow • Between C03 (3) and (16): 0.5 - 4.5 V • Between C03 (6) and (16): 18 - 28 V • Between C03 (female) (3) and (16), (3) and chassis: Min. 1 M Ω (Disconnect connectors C03 and C08.) 1. Takes pump pressure as 0 MPa {0 kg/cm2)} when actuating. # If the abnormality is restored by the vibration of the machine, the condition will return to normal when the power source is reset. (However, the service code does not go out.) 1.

The travel speed does not auto- matically shift (it does not change from Hi to Lo) # If the button is operated manually, the panel display is switched