TESTING AND ADJUSTING C-6 C-6 [E205] Short circuit in 2-stage relief solenoid system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code "E" is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check that the service code "E" is displayed. (If it is not displayed, the problem has been removed.) # Before carrying out troubleshooting, check that all the related connectors are properly inserted.
# Always connect any disconnected connectors before going on to the next step. operated + power max. switch ON Table 1 C-6 Related electrical circuit diagram A04 (KES1.2) 2. Step relief 20-183 3 YES Is resistance YES between C01 2 (female) (10) and Is resistance chassis normal? YES between V05 (male) • Turn starting switch NO (1) and (2), (2) and OFF 1 chassis as shown in • Disconnect C01 Table 1? • Turn swing lock switch OFF Interchange • Turn starting switch • 20 - 60 Ω connector with other OFF solenoid. Is [E205] • Disconnect V05 NO displayed?
• Turn starting switch OFF • Interchange V05 with NO other solenoid • Start engine • Work equipment control lever Cause Remedy Defective engine throttle, pump controller Wiring harness between C01 (female) (10) and V05 (female) (1) short circuiting with chassis ground Defective 2-stage relief solenoid (internal short circuit, short circuit with chassis ground) Replace Repair or replace Replace Between V05 (male) (1) and (2) 20 - 60 Ω Between V05 (male) (2) and chassis Min. 1 MΩ