TESTING AND ADJUSTING C-12 C-12 [E217] Model selection input error is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code "E" is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check that the service code "E" is displayed. (If it is not displayed, the problem has been removed.) # Before carrying out troubleshooting, check that all the related connectors are properly inserted.
# Always connect any disconnected connectors before going on to the next step. Table 1 Monitoring code display # The diagram shows monitoring code 02. # Check the bit pattern display marked with Table 2 Voltage of wiring harness 20-187 YES 1 Is monitoring mode display as shown in Table 1? 2 YES Is voltage between • Turn starting switch C17 (5) and chassis ON NO as shown in Table 2?
• Set to monitoring codes (02, 03 and 21, 22) • Turn starting switch NO ON Cause Remedy Defective governor, pump controller Defective model selection connector, or disconnection, short circuit with ground, or short circuit in wiring harness where voltage is defective Replace Repair or replace C17 Between (5) - chassis Voltage Max. 1 V