Komatsu — C- 13 [ E222] Short circuit in LS- EPC solenoid system is displayed

TESTING AND ADJUSTING C-13 C-13 [E222] Short circuit in LS-EPC solenoid system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code "E" is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check that the service code "E" is displayed. (If it is not displayed, the problem has been removed.) # Before carrying out troubleshooting, check that all the related connectors are properly inserted.

# Always connect any disconnected connectors before going on to the next step. Table 1 C-13 Related electrical circuit diagram (X2) 20-188 2 YES Is resistance C02 (female) (7) and (17), YES (7) and chassis as 1 shown in Table 1? Is resistance between C10 (male) (1) and (2), 91) and • Turn starting switch NO chassis as shown in OFF Table 1?

• Disconnect C02 • Turn starting switch OFF NO • Disconnect C10 Cause Remedy Defective engine throttle, pump controller Short circuit with ground, short circuit with power source in wiring harness between C02 (female) (7) and C10 (female)(91), or short circuit with power source in wiring harness between C02 (female) (17) and C10 (female) (2) Defective LS-EPC solenoid (internal disconnection, short circuit with power source) Replace Repair or replace Replace Troubleshooting 1 Troubleshooting 2 Resistance value Between C10 (male) (1) and (2) Between C02 (female) (7) and (17) 7 - 14Ω Between C10 (male) (1) and chassis Between C02 (female) (7) and chassis Min. 1 MΩ