TESTING AND ADJUSTING H-3, H-4 H-3 No work equipment, travel, swing move H-4 Abnormal noise generated (around pump) 20-213 YES 2 When main pump YES pressure pickup plug is removed, does oil 3 YES come out? 1 • Crank with starting Is PTO spline Is safety lock valve motor. NO normal? working properly? NO • Is valve working properly? NO Cause Remedy Defective control pump, control relief valve, or defective control circuit Defective main piston pump Defective PTO spline Defective operation of safety lock valve or safety linkage. Replace Repair or replace Repair or replace Adjust 3 YES Go to item 4 YES Do bubbles disappear when engine is stopped? 2 NO YES Are there bubbles inside hydraulic tank?
YES 1 4 Is suction strainer Is hydraulic tank oil clogged by external level normal? NO object? 5 YES Is suction strainer clogged with metal External object: particles or are metal Cloth, etc. NO particles stuck to drain plug? NO NO Cause Remedy Defective hydraulic oil Clogged by external object (cloth, etc.) Defect inside pump Operate for a short time and watch for any change in symptoms Lack of hydraulic oil Replace Change hydraulic oil Remove Repair or replace Inspect again (depending on changes in symptoms) Add hydrau- lic oil