Komatsu — H- 21 Excessive overrun when stopping swing

TESTING AND ADJUSTING H-21 H-21 Excessive overrun when stopping swing a) One direction only 2 YES Defective PPC valve Replace YES Is problem reversed when left and right output hoses of PPC valve are inter- changed? Does control valve spool move smoothly? 1 Defective swing motor safety valve Replace NO Defective operation of control valve spool. Correct or replace NO b) Both directions 20-230 Cause Remedy Cause Remedy Defective swing motor Correct or replace